A type of surface, flush, or freestanding raceway designed to hold conductors and receptacles, assembled in the field or at the factory.
Card 82
Question
Neutral Conductor
Answer
The conductor connected to the neutral point of a system that is intended to carry current under normal conditions.
Card 83
Question
Neutral Point
Answer
The common point on a wye-connection in a polyphase system or midpoint on a single-phase, 3-wire system, or midpoint of a single-phase portion of a 3-phase delta system, or a midpoint of a 3-wire, direct-current system.
Card 84
Question
Nonautomatic
Answer
Action requiring personal intervention for its control. As applied to an electric controller, nonautomatic control does not necessarily imply a manual controller, but only that personal intervention is necessary.
Card 85
Question
Nonlinear Load
Answer
A load where the wave shape of the steady-state current does not follow the wave shape of the applied voltage.
Card 86
Question
Outlet
Answer
A point on the wiring system at which current is taken to supply utilization equipment.
Card 87
Question
Outline Lighting
Answer
An arrangement of incandescent lamps, electric-discharge lighting, or other electrically powered light sources to outline or call attention to certain features such as the shape of a building or the decoration of a window.
Card 88
Question
Overcurrent
Answer
Any current in excess of the rated current of equipment or the ampacity of a conductor. It may result from overload, short circuit, or ground fault.
Card 89
Question
Service Equipment
Answer
The necessary equipment, usually consisting of a circuit breaker(s) or switch(es) and fuse(s) and their accessories, connected to the load end of service conductors to a building or other structure, or an otherwise designated area, and intended to constitute the main control and cutoff of the supply.
Card 90
Question
Service Lateral
Answer
The underground service conductors between the street main, including any risers at a pole or other structure or from transformers, and the first point of connection to the service-entrance conductors in a terminal box or meter or other enclosure, inside or outside the building wall. Where there is no terminal box, meter, or other enclosure, the point of connection is considered to be the point of entrance of the service conductors into the building.
Card 91
Question
Service Point
Answer
The point of connection between the facilities of the serving utility and the premises wiring.
Card 92
Question
Short-Circuit Current Rating
Answer
The prospective symmetrical fault current at a nominal voltage to which an apparatus or system is able to be connected without sustaining damage exceeding defined acceptance criteria.
Card 93
Question
Show Window
Answer
Any window used or designed to be used for the display of goods or advertising material, whether it is fully or partly enclosed or entirely open at the rear and whether or not it has a platform raised higher than the street floor level.
Card 94
Question
Signaling Circuit
Answer
Any electrical circuit that energizes signaling equipment.
Card 95
Question
Solar Photovoltaic System
Answer
The total components and subsystems that, in combination, convert solar energy into electric energy suitable for connection to a utilization load.
Card 96
Question
Special Permission
Answer
The written consent of the authority having jurisdiction.
Card 97
Question
Structure
Answer
That which is built or constructed.
Card 98
Question
Supplementary Overcurrent Protective Device
Answer
A device intended to provide limited overcurrent protection for specific applications and utilization equipment such as luminaires and appliances. This limited protection is in addition to the protection provided in the required branch circuit by the branch circuit overcurrent protective device.
Card 99
Question
Surge Arrester
Answer
A protective device for limiting surge voltages by discharging or bypassing surge current; it also prevents continued flow of follow current while remaining capable of repeating these functions.
Card 100
Question
Surge-Protective Device (SPD)
Answer
A protective device for limiting transient voltages by diverting or limiting surge current; it also prevents continued flow of follow current while remaining capable of repeating these functions and is designated as follows: Type 1: Permanently connected SPDs intended for installation between the secondary of the service transformer and the line side of the service disconnect overcurrent device. Type 2: Permanently connected SPDs intended for installation on the load side of the service disconnect overcurrent device, including SPDs located at the branch panel. Type 3: Point of utilization SPDs. Type 4: Component SPDs, including discrete components, as well as assemblies.