Card 141

Question

What is the maximum cabin climb/descent rate?

Answer

+500ft/min and -300ft/MIN

Card 142

Question

How is the DHE (Dual Heat Exchanger) provided with air during ground operation?

Answer

By an electric fan via the dorsal scoop

Card 143

Question

What is the purpose of the TCV (Temperature Control Valve)?

Answer

To regulate what mixing ratio of cool air from DHE and warm air from the ECS

Card 144

Question

What is the temperature range in each zone?

Answer

15-30 degrees

Card 145

Question

What is the requirement to run the electric air conditioning system?

Answer

QPM, Eng Gen, or GPU

Card 146

Question

What is the VCS (Vapor Cycle System)

Answer

A system where a refrigarant is passed in a closed system and which is cooled by expansion and compressed by a compressor in the rear compartment

Card 147

Question

If Emergency RAM Air is opened, is it possible to close it in flight?

Answer

No

Card 148

Question

For how long does the bleed overheat have to persist to have a CAS message posted?

Answer

10 seconds

Card 149

Question

What is the temperature threshold which will triger a leak in the Rear fuselage, right over-wing fairing and forward belly fairing

Answer

85 degrees

Card 150

Question

What is the temperature threshold which will triger a leak in the Pylon area?

Answer

130 degrees

Card 151

Question

What is the redundancy of the Fire warning channels?

Answer

There are two channels, one goes directly to the glareshield mounted indications, the second channel routes directly to the UMS.

Card 152

Question

How does the detector loop of the PC-24 work?

Answer

The detector consist of a sealed gas-filled tube which operates on the principle of gas expand with increase in temp and triggers a warning over a set-limit, both for overpressure and underpressure (leak)

Card 153

Question

What is the lenght of the fire detection loop?

Answer

4.2 m

Card 154

Question

How many pressure switches are the in the fire detection system?

Answer

Three

Card 155

Question

When is a fire detect signal triggered?

Answer

When any 5 inch segment reaches a temp of 510 +-40 degrees.

Card 156

Question

How many halon bottles installed?

Answer

Two

Card 157

Question

Does any systems interact with the triggering of the Extinguisher button?

Answer

For the first shot, it is triggered directly by the extinguish switch, then the UMS takes authority of the second shot and introduce a delay of 30 sec

Card 158

Question

What is the time delay between Engine isolation and first shot being armed?

Answer

5 sec

Card 159

Question

What happens during "Engine Isolation"

Answer

Fuel SOV is closed, Bleed Air SOV is closed and fire extinguishers are armed.

Card 160

Question

What does the "EMPTY" caption on the Fire Extinguisher Switch mean?

Answer

That both bottles are empty

How to use this set

Read the preview and check whether the content and answers suit your learning goal. You can add the public set to your sets to study it. Your account shows the available actions.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please reload the page.