CAT III DUAL without DH: Minimum Runway Visual Range
Answer
75 m, 75 m, 75 m
IF BA 6 or 5.
Card 82
Question
CAT III SINGLE With DH 50 - 100 ft: Minimum Runway Visual Range
Answer
175 m 75m, 75 m.
Card 83
Question
CAT III DUAL without DH: Minimum Runway Visual Range if BA is 4,3,2,1?
Answer
175m, 125m, 75m, 50 feet DA
Card 84
Question
IF you plan to land with NO DA, and BA is 4, what considerations regarding RVR?
Answer
RVR needs to be 175m, 125m and 75m
Card 85
Question
You plan to use ROLL OUT (CAT 3 DUAL) for a CAT 2 with OEI. What considerations with Crosswind?
Answer
For OEI Xwind limit is 15 kt IF AUTO ROLLOUT is used.
If AP is disconnected on Touch Down, the Cross Wind can be increased to 20 kt.
Card 86
Question
Engine-Out CAT II and CAT III fail passive autoland are only approved in configuratio
Answer
3 and FULL, and if engine-out procedures are completed before reaching 1 000 ft in approach.
Card 87
Question
Automatic Landing With a glide slope angle between
Answer
-2.5 ° and -3.25 °
Card 88
Question
Automatic Landing - With is aircaft minimum weight approved?
Answer
44 000 kg
Card 89
Question
Automatic Landing Can you land above MLW with automatic landing?
Answer
No
Card 90
Question
Automatic Landing Minimum acceptable Glideslope Height over Threshold (GHT)/Threshold Crossing Height (TCH) for automatic landing is?
Answer
33 ft.
Card 91
Question
Automatic Landing Automatic rollout performance is approved on dry and wet runways, but performance on contaminated runways
Answer
was not demonstrated.
Card 92
Question
During automatic rollout with one engine inoperative or one thrust reverser inoperative, the flight crew can use the remaining thrust reverser, provided that:
Answer
No more than idle thrust is used
Card 93
Question
Automatic landing system performance is demonstrated with CAT II or CAT III, but is allowed on a CAT 1 beam IF
Answer
Analysis is performed by SAS for all runways with CATII or CATIII approaches. Meaning that if the Runway is approved for CAT 2 or 3, and CAT 1 is in use. IT IS OK.
Otherwise NOT
Card 94
Question
Automatic Landing Autoland Databases with Honeywell ADIRU:
Answer
Is a table in FCOM where AUTOLAND and ROLL OUT is not allowed after a certain date
Card 95
Question
After three consecutive APU start attempts, the flight crew must wait
Answer
60 min before a new start attempt.
Card 96
Question
During refuel/defuel procedures, APU starts or shutdown are permitted with the following restrictions:
Answer
If the APU failed to start or following an automatic APU shutdown, do not start the APU
If a fuel spill occurs, perform a normal APU shutdown.
Card 97
Question
APU Battery restart limit (EMER CONFIG)
Answer
25000 ft
Card 98
Question
Max altitude for air conditioning and pressurization (single pack operation)
Answer
22500 ft
Card 99
Question
Apu can suppl ELEC power to what alt?
Answer
Above 39800 ft
Card 100
Question
APU Bleed Max altitude to assist engine start
Answer
20 000 ft
How to use this set